Biblioteca Hospital 12 de Octubre
Vista normal Vista MARC Vista ISBD

Augmentation mastopexy: maximal reduction and stable implant coverage using four flaps. [artículo]

Por: Vizán Aso, Jorge [Cirugía Plástica, Estética y Reparadora] | Iglesias Pena, Israel [Cirugía Plástica, Estética y Reparadora].
Colaborador(es): Servicio de Cirugía Plástica y Reparadora.
Tipo de material: materialTypeLabelArtículoEditor: Aesthetic plastic surgery, 2014Descripción: 38(4):711-7.Recursos en línea: Solicitar documento Resumen: Background: A single-stage operation to correct ptotic and hypoplastic breasts would appear to be a very appealing option for both surgeons and patients. However, this procedure is the most often litigated in aesthetic surgery because of its frequent complications. Our goal in this article is to report our experience with a four-flap technique for implant coverage in maximum reduction mastopexy with prosthesis. Methods: From January 2011 to March 2013, a total of 41 patients with Regnault grade II or grade III ptosis with no hypertrophy underwent primary bilateral augmentation mastopexy. Our technique includes an inverted-T mastopexy and a thin, well-vascularized, inferior dermoglandular flap to cover the inferior pole of the implant. Retrospective data collection revealed a mean patient age of 37.5 years. Thirty-nine patients were treated with round cohesive silicone gel implants and two with anatomical cohesive gel implants. The mean implant volume was 280 cc and mean follow-up time was 14 months. Results: The following complications were observed in declining frequency: four suture dehiscences, two hematomas, one capsular contracture, one implant malposition, and one poor scarring. A satisfaction questionnaire revealed very high satisfaction in 23 patients (56.09 %), high satisfaction in 12 (29.26 %), moderate satisfaction in four (9.75 %), and low satisfaction in two (4.87 %). Conclusions: Our results demonstrated a low complication rate (21.9 %) and low reoperation rate (12.1 %) with our technique and make us confident in recommending this technique for grade II and grade III ptosis.
Etiquetas de esta biblioteca: No hay etiquetas de esta biblioteca para este título. Ingresar para agregar etiquetas.
    valoración media: 0.0 (0 votos)
Tipo de ítem Ubicación actual Signatura Estado Fecha de vencimiento
Artículo Artículo PC15920 (Navegar estantería) Disponible

Formato Vancouver:
Forcada EM, Fernández MC, Aso JV, Iglesias IP. Augmentation mastopexy: maximal reduction and stable implant coverage using four flaps. Aesthetic Plast Surg. 2014 Aug;38(4):711-7.

PMID: 24938689

Contiene 39 referencias

Background: A single-stage operation to correct ptotic and hypoplastic breasts would appear to be a very appealing option for both surgeons and patients. However, this procedure is the most often litigated in aesthetic surgery because of its frequent complications. Our goal in this article is to report our experience with a four-flap technique for implant coverage in maximum reduction mastopexy with prosthesis.
Methods: From January 2011 to March 2013, a total of 41 patients with Regnault grade II or grade III ptosis with no hypertrophy underwent primary bilateral augmentation mastopexy. Our technique includes an inverted-T mastopexy and a thin, well-vascularized, inferior dermoglandular flap to cover the inferior pole of the implant. Retrospective data collection revealed a mean patient age of 37.5 years. Thirty-nine patients were treated with round cohesive silicone gel implants and two with anatomical cohesive gel implants. The mean implant volume was 280 cc and mean follow-up time was 14 months.
Results: The following complications were observed in declining frequency: four suture dehiscences, two hematomas, one capsular contracture, one implant malposition, and one poor scarring. A satisfaction questionnaire revealed very high satisfaction in 23 patients (56.09 %), high satisfaction in 12 (29.26 %), moderate satisfaction in four (9.75 %), and low satisfaction in two (4.87 %).
Conclusions: Our results demonstrated a low complication rate (21.9 %) and low reoperation rate (12.1 %) with our technique and make us confident in recommending this technique for grade II and grade III ptosis.

No hay comentarios para este ejemplar.

Ingresar a su cuenta para colocar un comentario.

Con tecnología Koha